Investigation into the Suitability of Powdery Glass as a Partial Replacement for Cement in Concrete
Adeniran Jolaade Adeniran, Joseph Olaoye & Abdulwaheed Olorukooba , August 2022, Published: 2023-02-12
Abstraction of materials for cement production largely results in environmental degradation hence the search for
substitute is necessary. Broken glass often litter construction site as environmental nuisance and health hazards. This
waste utilized, was crushed and finely ground by mechanical grinding machine. The powder generated was passed
through 75µm sieve size which falls within range of particle size of cement (50µm-90µm). Particle size distribution
was carried out on both fine and coarse aggregate in accordance with (BS 1377-2:1990); Workability test was also
carried out on concrete. Specific gravity was carried out on cement and fine aggregate. Concrete cubes were cast
replacing cement from 0% to 20% adopting a water cement ratio (W/C) of 0.5 and cured for 7, 14 and 28days
respectively. Water absorption and consistency test were carried out on conventional and modified concrete. The
result showed that particle size distributions of the aggregates are well graded. All the samples tested have true
slumps. Cement, fine aggregate and powdered glass specific gravities are 2.63, 2.65and 2.83 respectively. The result
showed that 10% replacement has higher water absorption rate of 1.11% while 5% replacement has lower water
absorption rate of 0.54%. The result further showed that control (0%) has compressive strength of 25MPa while at
5%, 10%,15% and 20% cement replacement compressive strength are 27.33MPa,25.58MPa, 22.18MPa and
18.26MPa respectively at 28days.The study concluded that the modified concrete at 28days, with 0.5 W/C ratio at 5%
and 10% cement replacement exhibits the similar properties of normal weight concrete.
Keywords: Waste glass, Cement, Workability, Compressive Strength, Water absorption